LMKA 2010 S Standard
Measuring length range
in mm:                  <= 9200
Measuring method:       absolute
Measuring principle:    inductive
Design of the scanning  Standard, without post 
head:                   processing of the mounting
                        holes on mounting side
Interface:              SSI (25 Data-Bit), 
                        additional incremental 
                        signals 1 Vpp
Ordering designation:   SSI-1Vpp
Interpolation factor    
digital:                10 Bit
Measuring step 1:       1000.0000 nm
Grating period:         1000 µm
Incremental signals:    ~ 1 Vpp
Signal period:          40.000 µm
Incremental signals /   multiplication:         
Max. scanning frequency:16.00 kHz
Power supply:           3.6 V ... 14 V DC
Electrical connection:  Coupling, M23 SpeedTEC, 
                        nickel-plated, with 
                        vibration O-ring, male, 
                        17-pin
Pin configuration:      D1184658
Cable length:           0.80 m
Included part and       Supplementary material 
packaging:              5300007