Electrical specification
Input section SUPPLY and ENCODER INPUT
Supply voltage +E Volt 9…30 Vdc, polarity protected
Current consumption without encoder 30 mA at 24 Vdc (Max. 60 mA)
Encoder signals Incremental HTL or RS422 levels
Mode 1 (default) 6 channels (S00, S00 inv, S90, S90 inv, Sref, Sref inv)
Mode 2 (Pin 3-4 bridged) 3 channels (S00, S90, Sref)
Output sections OUTPUT 1 and 2
Output level RS422 HTL
Supply voltage +E Volt 9…30 Vdc 9…30 Vdc
Load max ± 20 mA ± 40 mA
Max cable length 1 km (TIA-EIA-422-B) 200 m at 50 kHz
U_high >3.0 V > +E V- 2.0 V
U_Low <0.4 V < 1.15 V
Frequency range 0...300 KHz 0...300 kHz
Isolation voltage 1 kV 1 kV
Propagation delay, tpH
, tpL Max 1 us Max 1 us
Mechanical specification
Housing Plastic and Aluminium
Mounting DIN rail 7.5mm, DIN rail 15 mm
Weight 160 g
Temperature Operating: -25 ºC…+70 ºC, Storage: -40 ºC…+85 ºC
Dimensions 105x72x38 mm (Height, width, depth)
• Converter and/or splitter between HTL or RS422 signals
• Galvanically isolated between inputs/outputs
• Universal box for mounting on DIN-rail
• Power supply voltage 9...30 Vdc
Wire area 0.20 - 1.5 mm2 (IEC) / 24 - 16 AWG (UL)