LMKA 3010 HA High Accuracy
Scanning head for guided linear encoder
Measuring length range
in mm:                  <= 9200
Measuring method:       absolute
Measuring principle:    inductive
Design of the scanning  Guide carriage, connection
head:                   via spring element
Interface:              EnDat 2.2
Ordering designation:   EnDat22
Interpolation factor    
digital:                14 Bit
Measuring step 1:       100.0000 nm
Grating period:         1000 µm
Incremental signals:    without
Signal period:          0.000 µm
Incremental signals /   
multiplication:         no incremental signals
Safety concept:         Functional safety
Functional safety:      for applications up to: | 
                        SIL-2 according to EN 
                        61508 (further basis for 
                        testing: EN 61800-5-2) | 
                        Category 3, PL “d” 
                        according to EN ISO 
                        13849-1:2008
Max. scanning frequency:20.00 kHz
Power supply:           3.6 V ... 14 V DC
Electrical connection:  Coupling M12, male, 8-pin
Pin configuration:      D532351
Cable length:           0.50 m