LMK 1010 S Standard
Measuring method:       incremental
Measuring principle:    inductive
Design of the scanning  Miniaturized, cable outlet
head:                   tangential right, compact
                        connector with electronics
                        on cable, output D-sub at
                        height 8 mm
Grating period:         1000 µm
Interface:              TTL
Incremental signals /
multiplication:         250 fold
Signal period:          4.000 µm
Max. scanning frequency:20.00 kHz
Power supply:           5 V (+-10 %) DC
Electrical connection:  D-sub connector, 2-row,
                        without locking screws,
                        male, 15-pin
Pin configuration:      D1164661
Cable length:           3.00 m