WMK 2010 S Standard
Scanning head for modular angle encoders
Scanning arrangement:   Outside scanning
Measuring method:       incremental
Measuring principle:    inductive
Design of the scanning  Special design, 2D
head:                   graduation type 01
Line count:             256
Number of signal
periods:                256
Grating period:         1000 µm
Interface:              ~1 Vpp
Incremental signals /
multiplication:         without
Safety concept:         Analog signals (1 Vpp) can
                        be used for safety-related
                        equipment
Max. scanning frequency:100.00 kHz
Power supply:           4 V ... 7 V DC
Electrical connection:  Coupling M12, male, 12-pin
Pin configuration:      D1207480
Cable length:           1.00 m