AK LIF 17R
Scanning head for LIF incremental exposed linear
encoder
Signal period:            4.000 µm / 0,4 µm (after
                          interpolation)
Thermal coefficient of
linear expansion:         ~ 8·10-6K-1
Reference mark:           active
Output signal:            Square-wave signals, TTL
                          levels with 10-fold
                          interpolation
Max. scanning frequency:  100.00 kHz
Reference pulse width:    90°
Fault detection signal:   for disturbance LOW
Power supply:             5 V (+-5 %)
Cable type:               PUR Ø 4.5 mm flexible
Cable length:             1.00 m
Electrical connection:    D-sub connector, 2-row,
                          metal housing, design A,
                          with locking screws,
                          male, 15-pin
Pin configuration:        D1174999