LMKA 3110 S Standard
Scanning head for guided linear encoder
Measuring length range
in mm:                  > 9200
Measuring method:       absolute
Measuring principle:    inductive
Design of the scanning  Guide carriage, connection
head:                   via spring element
Interface:              SSI, additional
                        incremental signals 1 Vpp
Ordering designation:   SSI-1Vpp
Interpolation factor
digital:                10 Bit
Measuring step 1:       1000.0000 nm
Grating period:         1000 µm
Incremental signals:    ~ 1 Vpp
Signal period:          1000.000 µm
Incremental signals /
multiplication:         without
Safety concept:         Analog signals (1 Vpp) can
                        be used for safety-related
                        equipment
Max. scanning frequency:20.00 kHz
Power supply:           3.6 V ... 14 V DC
Electrical connection:  D-sub connector, 2-row,
                        with locking screws, male,
                        15-pin
Pin configuration:      D1187719
Cable length:           1.00 m