LMK 2030 S Standard
Measuring method:       incremental
Measuring principle:    inductive
Design of the scanning  Standard, cable outlet
head:                   tangential right,
                        connector with electronics
                        on cable, output D-sub
Grating period:         3000 µm
Interface:              TTL
Incremental signals /
multiplication:         250 fold
Signal period:          12.000 µm
Max. scanning frequency:2.50 kHz
Power supply:           5 V (+-10 %) DC
Electrical connection:  D-sub connector, 2-row,
                        without locking screws,
                        male, 15-pin
Pin configuration:      D1164661
Cable length:           3.00 m
Special characteristics,
scanning head:          Edge separation >= 0.4 µs