AE ECI 4090S
Scanning unit for absolute encoder with inductive
scanning
Positions per revolution: 1048576
Data interface:           DQ01 DRIVE-CLiQ encoder
                          interface DQ01
Output code:              Binary
Power supply:             10 V ... 28.8 V
Form of scanning unit:    Inside Ø 114.2 mm,
                          outside Ø 142 mm (ring),
                          outside Ø 174 mm (with
                          head), hole circle Ø 129
                          mm, holes 6x M4, drum
                          height 20 mm
Drum outside diameter:    112.80 mm
Degree of protection:     IP40 (EN60529)
Operating temperature:    -40/+100 °C
Electrical connection:    Plug connector,
                          straight, double-row,
                          15-pin
Pin configuration:        D1079827
Connecting direction:     Cable outlet right
Safety concept:           Functional safety
Please pay attention to the product documentation!